Call 08048973588 79% Response Rate

our range

Electro Chemical Instruments

Owing to our expertise in this discipline, we have been able to bring forth the best-in-class Electro Chemical Instruments. This offered range includes Multi Parameter Meter, Lab pH Meter, Conductivity Meter, dissolved Oxygen Meter, ORP Meter, Ion Concentration Meter and many others. Furthermore, to deal with the various individual demands of the clients, we offer these products in different sizes and specifications. Manufactured using high-grade required basic material and components, these products satisfy defined quality benchmarks of the industry.

Lab PH Meter Precision

Lab PH Meter Precision

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
pH Range0-14pH
Temperature CompensationAutomatic or Manual
Meter Weight700 g
Mv Accuracy+1mV
ModelCpH-102
pH Resolution+0.01pH
pH Accuracy+0.002pH
Temperature Range0 - 100 deg C
mV Resolution1mV
ElectrodepH combination electrode with built in temperature sensor, Plastic - EpHP02
Electrode TemperatureBuilt in
Meter Dimensions165 (L) x 190 (D) x 60 (H) mm

Lab PH Meter Precision, an advanced Benchtop pH Meter is the perfect combination of the state of the art electronic design coupled with advanced software & reliable electrochemical sensor higher user a combination plastic pH electrode with an inbuilt temperature sensor for the simultaneous measurements of pH &temperature &automatic temperature correction. CpH-103, a higher-end bench pH Meter incorporates a glass electrode &separate temperature sensor for high accuracy pH measurement & automatic temperature compensation.

These pH meters cover innumerable applications in Research, Education, Chemical, Pharmaceutical, Food processing, Cosmetic, Biological & Agricultural fields.


Features :

  • pH , mV and Temperature measurement.
  • Automatic or Manual temperature Compensation.
  • 3 point pH calibration.
  • Buffers selectable from 1.68pH, 4.00pH, 4.01pH, 6.86pH, 7.00pH, 9.18pH, 9.20pH. 10.01pH and 12.45pH
  • Automatic buffer recognition.
  • Bi-directional RS-232 interface. Baud rate selectable from 1200,2400,4800 and 9600.
  • Single and continuous print out of measuring parameters.
  • Multiple Printout types. Combinations selectable from Sr. No., pH, mV, Date, time and temperature.
  • Real Time Clock.
  • Calibration report as per GLP requirements.
  • Electrode Slope and mV offset display.
  • Memory storage of 100 measurements.
  • Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, the 20S, 30S, 1M, 2M, and 5M.
  • Temperature calibration with respect to the solution of known temperature.

 

Details:

Model
CpH-102CpH-103
pH Range
0-14pH-2.0000~19.999pH
pH Resolution
+0.01pH0.001pH
pH Accuracy
+0.002pH+0.002pH
Temperature compensation
Automatic or ManualAutomatic or Manual
Temperature range
0~100o C0~100o C
mV Range.1mV+1999mV+1999.9mV
mV Resolution
1mV0.1mV
mV Accuracy
+1mV+0.5mV
Electrode
pH combination electrode with
built in temperature sensor
- Plastic-EpHP02
pH combination electrode
- Glass -EpHG03
Temperature Electrode
Built inTemperature sensor electrode
Meter Dimensions (mm)
165 (L) x 190 (D) x 60 (H)165 (L) x 190 (D) x 60 (H)
Meter Weight
700 g700 g


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6 weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back
Dissolved Oxygen Meter

Dissolved Oxygen Meter

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
Operating Temperature15 - 45 deg C
Temperature+/-0.4 deg C
Measurement RangeDO: 0~40.00mg/L (ppm), 0~200.0%
ElectrodeDO electrode-EDO01
Magnetic StirrerMS-01
PrecisionDO: +/-0.10 mg/L
Temperature CorrectionAutomatic 0~45 deg C
Salinity CorrectionAutomatic 0~45 ppt
Air Pressure CorrectionAutomatic 80 ~ 105kPa
DisplayBacklight LCD
Power9V/ 500mA External adaptor or Battery backup unit (Optional)
Meter Dimension165(L) x 190(D) x 60(H) (mm)
Meter Weight700g
CONTECH Dissolved Oxygen Meter incorporates membrane electrode method to measure dissolved oxygen concentration and saturation of water solution. Polarographic type dissolved oxygen electrode offers quick response, accurate measurement, short polarization time along with features for automatic salinity and temperature compensation & air pressure compensation with the help of built-in air pressure sensor. DO meters are useful for aquaculture, monitoring of water resource, beverage production, sewage disposal, biological agriculture, environmental protection and scientific research.

Features:

  • Dissolved oxygen and temperature measurement.
  • Polarographic type DO electrode offers short polarization time, quick response and precise measurements.
  • Easy to use electrode calibration sets and diaphragm cap.
  • Dissolved oxygen electrode with the salinity measurement feature can achieve automatic salinity & temperature compensation.
  • Automatic air pressure correction with the help of air pressure sensor.
  • Bidirectional RS232 interface. Baud rate selectable from 1200, 2400, 4800 and 9600.
  • Single and continuous print out of readings.
  • Multiple Printout types. Combinations selectable from different measuring parameters.
  • Real Time Clock. Calibration report as per GLP requirements.
  • Memory storage of 100 test results.
  • Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, the 20S, 30S, 1M, 2M and 5M.
  • Supplied with Magnetic Stirrer MS-01 as standard.


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 100
  • Delivery Time: 5-6 weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back
Multi Parameter Meter

Multi Parameter Meter

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
pH-2.0000 - 19.999 pH
mV+1999.9mV
Conductivity0 - 2000 mS / cm spread into 6 ranges 0.00 - 20.00 microS/cm, 20.0 - 200.0 microS/cm
Resistivity0 - 100 M ohm cm
TDS0 - 100 g/L
Salinity0 - 100 ppt, 0 - 200.0%
DO0 - 40.00 mg/L (ppm)
Ion0.00 - 14.00 pX (units pX, mg/L, ppm)
Temperature-10.0 - 110.0 deg C

Contech Multi Parameter Meter is the perfect combination of advanced Electrochemical sensor technology with state of the art electronics and software design. This instrument can measure several parameters, like pH, mV, Conductivity TDS, Salinity, Resistivity, Dissolved oxygen, Ion concentration and temperature using different electrodes.

Features:

  • pH, mV, Conductivity, Resistivity, TDS, Salinity, DO, Ion Concentration, Temperature modes. Automatic or Manual temperature Compensation. 3 point pH calibration.
  • Buffers selectable from 1.68pH, 4.00pH, 4.01pH, 6.86pH, 7.00pH, 9.18pH,9.20pH. 10.01pH and 12.45pH
  • Automatic buffer recognition.
  • 1 point conductivity calibration for the entire range. Dissolved oxygen electrode with the salinity measurement feature to achieve automatic salinity & temperature compensation.
  • Automatic air pressure compensation for DO with the help of air pressure sensor.
  • Polarographic type DO electrode offers short polarization time, quick response and precise measurements. 2 point Ion concentration standard solution calibration. Switching option among 3 measurement units of Ion concentration, pX,mg/L, ppm.
  • Bi directional RS-232 interface. Baud rate selectable from 1200,2400,4800and 9600. Single and continuous print out of measuring parameters. Multiple Printout types. Combinations selectable from Sr. No., pH, mV, conductivity, TDS, Salinity, DO, Ion Concentration, Date, time and temperature. Real Time Clock.
  • Calibration report as per GLP requirements.Electrode Slope and mV offset display. LCD display with Backlite. Memory storage of 100 measurements. Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, 20S, 30S, 1M, 2M and 5M. Temperature calibration with respect to solution of known temperature.


Details:

pHmVConductivityResistivityTDSSalinityDOIonTemp
Range-2.0000~
19.999pH
+1999.9mVConductivity :
0~2000mS/cm spread
into 6 ranges
0.00~20.00µS/cm,
20.0~200.0 µS/cm,
200~2000 µS/cm
2.00~20.00mS/cm,
20.0~200.0 mS/cm,
200~2000mS/cm(K=10)
0~100MΩcm0~100g/L0~100ppt
0~200.0%
0~40.00mg/L(ppm),0.00~14.00pX
(units pX, mg/L, ppm)
-10.0 ~ 110.0oC
Accuracy+0.002pH+0.5mV+0.5% FS+0.10 mg/L+0.5% of reading
value (monovalent),
+1% of reading
value (bivalent)
+0.4oC
ATC0~100 oC0~100 oC0~50 oC0~50 oC0~50 oC0~50 oC0~45 oC0~60 oC
ElectrodeEpHG03EpHG03ECNG01ECNG01ECNG01ECNG01


Additional Information:

  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6 weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back
Ion Concentration Meter

Ion Concentration Meter

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
ModelCICNa
Measurement ParametersNa+ concentration, mV, Temp
ElectrodesEINaG01(Sodium Ion Electrode), ERG02(Reference Electrode), ETS01(Temperature Electrode)
Standard AccessoriesMS-01(Magnetic Stirrer)
Power9V/ 500mA External adaptor or battery backup unit. (Optional)
Operating Temperature15 to 45 deg C
Meter Dimension165(L) x 190(D) x 60(H) mm
Meter Weight700g
Measuring UnitspNa, mg/L, ppm
Measuring Range0.00~9.00 pNa
mV Range+/-1999.9mV
Temperature Range-10 to 110 deg C
Measurement Accuracy+/-0.01pNa
mV Accuracy+/-0.1% FS
Temperature Accuracy+/- 0.5 deg C
ATC Range0 - 50 deg C

CONTECH Laboratory Ion Concentration Meter when used with particular Ion-selective electrodes and corresponding reference electrodes can measure the correspondent electrode potential mV value, pX value, and Ion Concentration. These instruments are useful in the field of Food Safety, Petrochemical, Water quality checking, Aqua Culture, Biological Agriculture, Environmental Protection and Research and Education.

 

Features :

  • Concentration unit mv & temperature measurement.
  • 2 point Ion concentration standard solution calibration.
  • Automatic or Manual temperature Compensation
  • Bi directional RS232 interface. Baud rate selectable from 1200, 2400, 4800 and 9600.
  • Single and continuous print out of readings.
  • Multiple Printout types. Combinations selectable from Sr. No., concentration unit, mV and temperature.
  • Real Time Clock. Calibration report as per GLP requirements.
  • LCD display with Backlight.
  • Memory storage of 100 measurements.
  • Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, 20S, 30S, 1M, 2M and 5M.
  • Temperature calibration with respect to solution of known temperature.

 

Details:

Model

CICNa

CICCa

CICF

Measurement parameters

Na+ concentration, mV, Temp

Ca2+ concentration, mV, Temp

F- concentration, mV, Temp

Measuring Units

pNa, mg/L, ppm

pCa, mg/L, ppm

pF, mg/L, ppm

Measuring Range

0.00~9.00 pNa

0.00~9.00 pCa

0.00~9.00 pF

mV Range

+/-1999.9mV

+/-1999.9mV

+/-1999.9mV

Temperature Range

-10~ 110oC

-10~ 110oC

-10~ 110oC

Measurement Accuracy

+/-0.01pNa

+/-0.01pCa

+/-0.01pF

mV Accuracy

+/-0.1% FS

+/-0.1% FS

+/-0.1% FS

Temperature Accuracy

+/-0.5 oC

+/-0.5 oC

+/-0.5 oC

ATC Range

0~50 oC

0~50 oC

0~50 oC

Electrodes

EINaG01(Sodium Ion Electrode), ERG02(Reference Electrode), ETS01(Temperature Electrode)

EICaP01(Calcium combination Electrode),

ETS01(Temperature Electrode)

EIFC01(Fluoride Ion Electrode),

ERG01 (Reference electrode)

ETS01(Temperature Electrode)

Standard Accessories

MS-01(Magnetic Stirrer)

MS-01(Magnetic Stirrer)

MS-01(Magnetic Stirrer)

 



Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6 Weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back
ORP Meter

ORP Meter

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
Power9V / 500 mA External adapter or battery backup unit (Optional)
pH Range0 - 14 pH
Operating Temperature15 - 45 deg C
DisplayBacklight LCD, Character Height
Temperature CompensationAutomatic or Manual
Meter Weight700 g
pH Resolution0.01 pH
pH Accuracy+/- 0.01 pH
Temperature Range0 to 100 deg C
ORP Range+/- 2000 mV
ORP Resolution1 mV
ORP Accuracy+/- 1mV
Input ResistanceGreater than 1 x 1012 ohms
Meter Dimensions165(L) x 190(D) x 60(H) mm
ORP ElectrodeORP Combination Electrode EORP-01 Temperature Electrode ETS01

Contech ORP Meter combined with EORP-01 electrode is used for the measurement of pH and oxidation reduction potential (ORP) in liquids. These ORP meters are mainly used in common solution and waste water testing.


Features:

  • pH, Rel.mV and temperature measurement.
  • Automatic or manual temperature compensation.
  • 3 point pH calibration.
  • Buffers selectable from 1.68pH, 4.00pH, 4.01pH, 6.86pH, 7.00pH, 9.18pH, 9.20pH. 10.01pH and 12.45pH
  • Automatic buffer recognition.
  • Bi directional RS232 interface. Baud rate selectable from 1200,2400,4800 and 9600.
  • Single and continuous print out of pH/Rel.mV.
  • Multiple Printout types. Combinations selectable from Sr. No., pH, Rel.mV, Date, time and temperature.
  • Real Time Clock. Calibration report as per GLP requirements.
  • Electrode Slope display.
  • Memory storage of 100 measurements.
  • Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, 20S, 30S, 1M, 2M and 5M.
  • Temperature calibration with respect to solution of known temperature.


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6 weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back
Conductivity Meter

Conductivity Meter

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
Conductivity+/- 0.5% FS
Power9V/500mA External adaptor or battery backup unit (Optional)
Resistivity0 - 1000 m ohm cm
Salinity0 - 100 ppt
Temperature-10.0 to 110.0 deg C
ATC0 - 50 deg C
DisplayBack lite LCD
Operating Temperature15 - 45 deg C
Meter Dimensions165 (L) x 190 (D) x 60 (H) mm
Meter Weight700 g
ElectrodeConductivity electrode - ECNG01 Temperature sensor electrode - ETS01
Contech Laboratory Conductivity Meter can measure Conductivity, Resistivity, Total Dissolved Solids(TDS), Salinity & Temperature of any solution. This instrument is suitable in the field of water quality monitoring, aquaculture, biological agriculture, scientific & educational research, food safety, petrochemical and environmental protection. It uses ECNG01 glass electrode with a platinum plate sensitive element coated with platinum black to avoid errors due to polarization especially in solutions of high conductivity.


Features:

  • Conductivity, resistivity, total dissolved solids(TDS),salinity & temperature measurement.
  • Automatic or manual temperature compensation
  • 1 point calibration for the entire range.
  • Bi directional RS232 interface. Baud rate selectable from 1200, 2400, 4800 and 9600.
  • Single and continuous print out of readings.
  • Multiple Printout types. Combinations selectable from different measuring units.
  • Real Time Clock. Calibration report as per GLP requirements.
  • Memory storage of 100 measurements.
  • Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, 20S, 30S, 1M, 2M and 5M.
  • Temperature calibration with respect to solution of known temperature.


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6 weeks
  • Packaging Details: Export Quality Packing

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES