We hold all the aces in designing and developing a remarkable Gas Analyzer. In this range, we offer Infrared Biogas Analyzer, Infrared Fluegas Analyzer, Infrared Coal Gas Analyzer, Automobile Emission Gas Analyzer and Leakage Gas Transmitter. These aforementioned products are fabricated by making use of supreme quality required basic material, procured from the accredited vendors of the markets. Furthermore, we design all our products in tune with the defined quality parameters of the industry, followed by a extensive R&D study. More information on offered products is provided below:



Infrared Flue Gas Analyzer
Ask for Price

Infrared Flue Gas Analyzer

We hold expertise in developing upgraded Infrared Flue Gas Analyzer. These products are manufactured with utmost precision in adherence with the defined parameters of the industry. Designed to perfection, these products are measures the gas concentration of CO, CO2, CH4 and C3H8 based on NDIR technology, concentration of H2 based on TCD and concentration of O2 based on ECD. NDIR principle is based on measurement of absorption spectrum intensity of wavelength of infrared light through a gas, the attenuation intensity of light dependent on the gas density in compliance with Lambert – Beer’s Law.n Our products are suitable to used in industries such as iron & steel, ferro alloys during smelting process gas analysis of sponge iron including blast furnace, coke oven, heat treatment, gas furnace, calcium carbide furnace, flue gas composition measurement in cement shaft kiln, gas analysis of straw biomass gasification process and analysis of industrial gases in environmental protection.

The Infrared Flue Gas Analyzer that we offer is used in different industrial sectors including iron and steel, sponge iron and ferro alloys in order to check the concentration of gases like oxygen, hydrogen, carbon monoxide and carbon dioxide. This equipment provides accurate measurement results.

Features :

  • Inbuilt sampling pump
  • LCD display

 

Specifications:

 

Measuring GasTechnologyRangeResolutionAccuracy
SO2NDIR0-2000ppm1 ppm+1%
NONDIR0-2000ppm1 ppm+1%
CONDIR0-5000ppm1 ppm+1%
CO2NDIR0-25%0.01%+2%
O2ECD0-25%0.01%+3%
NOx (Optional)Catalytic Gas
Conversion
0-5000ppm1 ppm+2%


Other Information
  • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
  • Minimum Order Quantity: 1 Piece
  • Port of Dispatch: JNPT Navi Mumbai
  • Production Capacity: 50
  • Delivery Time: 5-6
  • Packaging Details: Export Quality Packing


Download




Infrared Coal Gas Analyzer
Ask for Price

Infrared Coal Gas Analyzer

We offer the best quality Infrared Coal Gas Analyzer to our clients at an affordable price. The equipment that we offer is highly accurate and offers authentic results in the measurement of the concentration of gases like hydrogen, oxygen and carbon dioxide. The equipment is reliable enough and can be used without any concern.
Infrared biogas analyzer measures the gas concentration of CO2, CHbased on NDIR technology,concentration of H2S and O2based on ECD (simultaneous measurement of 4 gases). Single Source duel beam non dispersion infrared (NDIR) principle is based on measurement of absorption spectrum intensity of wavelength of infrared light through a gas, the attenuation intensity of light dependent on the infrared gas concentration. This online product is used to detect the concentration of CO2, CH2, H2S and O2 produced in the biogas and landfill gas. Main applications are biogas plants anaerobic digestion, sewage treatment plants, sludge digestion, bio methane production plants, landfill sites, etc.  
Features:

  • Can measure concentration of CO2, CH4 based on duel beam infrared NDIR, concentration of H2S and O2 based on ECD simultaneously.
  • Inbuilt sampling pump with relay and solenoid valve. 
  • Alarm with relay output – 2nos per measuring channel at presettable gas concentrations (Optional).
  • Large LCD display.
  • RS232 interface & 4-20 mA output (optional).
  • Programmable auto zero function
  • SS connectors for gas inlet / outlet connectors. 

Specifications:

    Measurement Gases & : CO2, CH4 (NDIR)

      (Technology)            H2S, O2 (ECD)              

        Measuring Range : CO2: 0~100%, CH4: 0~100%, H2S: 0~9999PPM, O2: 0~25%

            Measurement range can be customized based 

              on the requirement.

              Resolution                   :  CO2, CH4, O2: 0.01%, H2S: 1PPM

                Accuracy                    : CH4, CO2: + 2%FS

                                                     O2, H2S: +3%FS

                    Sampling Gas Requirement  : Free from dust, water vapor and oil.

                      Flow Rate                        : 0.7~1.2 ltr. /min

                        Inlet Pressure                   : 2kPa~50kPa

                          Response Time               : 15 sec. (NDIR & O2 ) & 60 sec. (H2S)      

                            Power supply                    : AC 220+10%V, 50Hz

                              Temperature                     : 0 ~50oC

                                Relative Humidity               : 85%

                                  Ambient Air Pressure          : 86~108kPa

                                    Dimensions          : 485(L)*457(W)*132(H)mm

                                      Weight                            :  12kg



                                      Other Information
                                      • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                      • Minimum Order Quantity: 1 Piece
                                      • Port of Dispatch: JNPT Navi Mumbai
                                      • Production Capacity: 20
                                      • Delivery Time: 5-6 weeks
                                      • Packaging Details: Export Quality Packing


                                      Download




                                      Infrared Biogas Analyzer
                                      Ask for Price

                                      Infrared Biogas Analyzer

                                      We are instrumental in offering qualitative range of Infrared Biogas Analyzer to our clients. Manufactured using supreme quality required basic material, these offered products are used to measure the gas concentration of CO2, CH4 based on NDIR technology, concentration of H2S and O2 based on ECD. Based on NDIR principle of absorption spectrum intensity of wavelength of infrared light through a gas, the attenuation intensity of light dependent on the gas concentration in compliance with Lambert – Beer’s Law. The offered products are used to detect the concentration of CO2, CH4, H2S and O2 produced in the bio-gas and landfill gas. It is used in the environmental monitoring and protection.

                                      Features:

                                      • 5 gas measurement
                                      • Sampling pump
                                      • LCD with back light

                                       

                                        Specifications:

                                        MeasuringTechnologyRangeResolutionAccuracy
                                        Gas



                                        So2Micro flow ndir0-2000ppm1 ppm+1%
                                        NoMicro flow ndir0-2000ppm1 ppm+1%
                                        CoMicro flow ndir0-5000ppm1 ppm+1%
                                        Co2Ndir0-25%0.01%+1%
                                        O2Ecd0-25%0.01%+3%
                                        NoxCatalytic gas0-5000ppm1 ppm+2%


                                        Other Details:

                                        • Sampling gas requirement: Free from dust, water vapour and oil
                                        • Flow rate: 0.7~1.2 ltr/min
                                        • Inlet pressure: 2kPa~50kPa
                                        • Response time: 15 secs
                                        • Power Supply: AC 220+10%V, 50Hz, Inbuilt Li-ion Battery.
                                        • Temperature: 0~50oC
                                        • Relative Humidity: 85%
                                        • Ambient Air Pressure: 86~108kPa
                                        • Dimensions: 450(L) x 350(W) x 180(H) mm
                                        • Weight: 10kg


                                        Other Information
                                        • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                        • Minimum Order Quantity: 1 Piece
                                        • Port of Dispatch: JNPT Navi Mumbai
                                        • Production Capacity: 50
                                        • Delivery Time: 5-6 Weeks
                                        • Packaging Details: Export Quality Packing


                                        Download




                                        Automobile Emission Gas Analyzer
                                        Ask for Price

                                        Automobile Emission Gas Analyzer

                                        Those who want to buy Automobile Emission Gas Analyzer can easily opt for our service. This premium quality analyzer is designed according to the norms and the demands of the market. This product can be used in various industries like automobile factories, service centers and pollution testing centers.

                                        This compact economic model is designed to make it a portable equipment. 

                                        This instrument finds application in Automobile Industry to check the emission in automobile emission checking station &  automobile service centers vehicle pollution monitoring units, etc. 


                                        Features :

                                        • Compact, portable, ergonomic design.
                                        • Unique infrared NDIR gas sensor for CO, CO2, HC and electrochemical (ECD) sensor for O2 & NO. Can measure concentration of CO, CO2, HC, O2 & NO(optional) simultaneously.
                                        • Air to fuel ratio (lambda) calculation and display 
                                        • Auto zero setting with air. 
                                        • Selection of fuel: petrol, LPG, Natural Gas, PET (C3/C6) user specified fuel.
                                        • Oil temperature and RPM data interface.(Optional) 
                                        • Printer (Optional)
                                        • Specialized Thermal conductivity cell least affected by gas flow variations.
                                        • Graphical(320x240) LCD with backlite.
                                        • RS-232 Interface



                                        Technical Specifications:

                                        Measurement Gases & (technology)  : CO, CO2, HC (NDIR), O2 & NO (ECD)

                                        Measuring Range : CO : 0~10%, CO2 : 0~20%,  O2 : 0~25%, HC : 0~9999ppm 
                                                                                        NO : 0~5000ppm (optional)

                                        Resolution                     : CO, CO2, O2 :0.01% , HC & NO : 1ppm

                                        Accuracy                            CO: +0.06%, CO2 : +0.5%, O2 : +0.5%  

                                                                                 HC: +12ppm, NO+25 ppm

                                        Sampling Gas Requirement : Free from dust, water vapor and oil.

                                        Response Time         :       15 secs.         

                                        Power supply               : AC 220+-10%V, 50Hz, Inbuilt Li-zon Battery.

                                        Temperature                : 0 -500C

                                        Relative Humidity        : 85%

                                        Dimensions   : 265X360X180mm

                                        Weight                       : 8 kg

                                         

                                        Applications:

                                        • Automobile Industry to check the emission in automobiles, emissions checking stations, automobile service centers & vehicle pollution monitoring unit


                                        Other Information
                                        • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                        • Minimum Order Quantity: 1 Piece
                                        • Port of Dispatch: JNPT Navi Mumbai
                                        • Production Capacity: 20
                                        • Delivery Time: 5-6 weeks
                                        • Packaging Details: Export Quality Packing


                                        Download




                                        Gas Detector - Hand Held
                                        Ask for Price

                                        Gas Detector - Hand Held

                                        The Hand Held Gas Detector that we offer the best in the market and clients can easily rely on this product for the best results. This unique product is widely used in different industrial sectors including LPG stations, metallurgy, mining, transportation, oil and gas and chemical companies. Clients can be rest assured that they can have the best products from us.

                                        Features :
                                        • High Precision and Reliable NDIR principle for CH4/CO2 & ECD principle for CO/H2S  
                                        • Preliferation sampling method
                                        • Display of gas concentration value


                                        Specifications:
                                        • Measurement Gases: NDIR for CH4/CO2 & (technology) ECD for CO/H2S
                                        • Measuring Range: 0~10% vol, 10~100% vol
                                        • Resolution: 0.01% in the range of 0~10% vol, 0.1% in the range of 10~100% vol
                                        • Accuracy: +1% FS
                                        • Response time: 25 secs at 250C

                                        Applications :
                                        Chemical industries, oil & gas storage and transportation,mining, metallurgy, LPG stations, spray painting, leakage of natural gas, etc.

                                        Other Information
                                        • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                        • Minimum Order Quantity: 1 Piece
                                        • Port of Dispatch: JNPT Navi Mumbai
                                        • Production Capacity: 20
                                        • Delivery Time: 5-6 weeks
                                        • Packaging Details: Export Quality Packing


                                        Download




                                        Leakage Gas Transmitter
                                        Ask for Price

                                        Leakage Gas Transmitter

                                        With the support of our team, we have been able bring forth Leakage Gas Transmitter with advanced effective technology, these products are in compliance with the defined parameters of the industry. Furthermore, our products are widely acclaimed for their significant performance and longer serviceability.

                                         

                                        Applications:

                                        Gas transmitters are widely used for the continuous monitoring of gas concentration in petrochemical process industries, mining and metallurgy, leakage of natural gas, petrol and gas storage, transportation and distribution, power generation, marine and cargo handling and oil rigs, etc.

                                         

                                          Features :

                                          • High Precision and Reliable NDIR principle for CH4/CO2 & ECD principle for CO/H2S
                                          • Preliferation sampling method
                                          • Display of gas concentration value

                                           

                                            Specifications :

                                            Measurement Gases : NDIR for CH4/CO2 &
                                            & (technology) ECD for CO/H2S
                                            Power Supply : 8~25 V DC
                                            Measuring Range : 0~5% vol
                                            5~100% vol
                                            Resolution : 0.01% in the range of 0~5% vol
                                            0.1% in the range of 5~100% vol
                                            Accuracy : +1% FS
                                            Response time : 25 secs at 250C



                                            Other Information
                                            • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                            • Minimum Order Quantity: 1 Piece
                                            • Port of Dispatch: JNPT Navi Mumbai
                                            • Production Capacity: 100
                                            • Delivery Time: 5-6 weeks
                                            • Packaging Details: Export Quality Packing


                                            Download




                                            Flue/Coal/Bio Gas Analyzer
                                            Ask for Price

                                            Flue/Coal/Bio Gas Analyzer

                                            Portable Infrared Flue Gas Analyzer measures the concentration of gases like SO2 , NO, CO, CO2, O2 (5 gases) simultaneously in a gas sample with optional measurement of gas temperature, pressure & flow testing function. Measurement of SO2, NO, CO & CO2
                                            is based on Micro Flow NDIR (Non Dispersive Infrared)method & O2 is based on Electro Chemical Detector (ECD).

                                            Features :

                                            • Based on micro flow NDIR gas sensor technology. Optional
                                            • Catalytic NOx converter (for NO2 to NO conversion in ppm range)
                                            • Measures concentration of SO2, NO, CO, CO2 & O2
                                            • - 5 gases simultaneously.
                                            • Measurement of temperature, pressure and flow function of gases (Optional).
                                            • Moisture in the sample does not effect SO2 & NO measurement.
                                            • Zero calibration with fresh air.
                                            • Sampling pump (Optional).
                                            • Graphical(320x240) LCD with backlite.
                                            • Calculation of combustion efficiency.
                                            • RS-232 Interface.
                                            • Works on AC adopter & battery. Battery gets charged while
                                            • instrument is powered through AC adopter.

                                            Specifications :

                                            • Sampling gas requirement : Free from dust, water vapour and oil.
                                            • Flow rate : 0.7~1.2 ltr/min
                                            • Inlet pressure : 2kPa~50kPa
                                            • Response time : 15 secs
                                            • Power Supply : AC 220+10%V, 50Hz, Inbuilt Li-ion Battery.
                                            • Temperature : 0~50oC
                                            • Relative Humidity : 85%
                                            • Ambient Air Pressure : 86~108kPa
                                            • Dimensions : 450(L) x 350(W) x 180(H) mm
                                            • Weight : 10kg

                                            Gas Concentration Measurement
                                            Measuring Technology Range Resolution Accuracy
                                            Gas

                                            • SO2 Micro Flow NDIR 0-2000ppm 1 ppm +1%
                                            • NO Micro Flow NDIR 0-2000ppm 1 ppm +1%
                                            • CO Micro Flow NDIR 0-5000ppm 1 ppm +1%
                                            • CO2 NDIR 0-25% 0.01% +1%
                                            • O2 ECD 0-25% 0.01% +3%
                                            • NOx Catalytic Gas 0-5000ppm 1 ppm +2%
                                            • (Optional) Conversion


                                            Other Information
                                            • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Other
                                            • Minimum Order Quantity: 1 Piece
                                            • Port of Dispatch: JNPT Navi Mumbai
                                            • Production Capacity: 50
                                            • Delivery Time: 5-6 weeks
                                            • Packaging Details: Export Quality Packing


                                            Download








                                             

                                            Contact Us

                                            Contech Instruments Limited
                                            V.N. Holla (CEO)
                                            207, Namdhari Chamber, 9/54, D.B. Gupta Road, Karol Bagh
                                            Delhi - 110005, India

                                            Contact via E-mail

                                            Contact via SMS


                                            Home|Profile|Our Products|Site Map|Contact Us|Mobile Site
                                            Member IndiaMART.com © Contech Instruments Limited. All Rights Reserved (Terms of Use)
                                            Developed and Managed by IndiaMART InterMESH Limited